P1NS101 Through-Beam Sensor
Through-Beam Sensor
In Stock
$103.00
per unit
Applications: Sensors & I/O
Description
The through-beam sensor works with red light as well as a transmitter and a receiver. Thanks to their high light intensity, the sensor provides a high degree of operational reliability even with interferences like steam, fog or dust. The transmitter can be deactivated using test input in order to test the functionality of the through-beam sensor. The IO-Link interface can be used to configure the sensor (PNP/NPN, NC/NO, switching distance), as well as for reading out switching statuses and signal values.
Features at a Glance
- Condition monitoring
- High light intensity with large switching reserve
- IO-Link 1.1
- Test input for high operational reliability
Technical Data
Optical Data
| Range | 20,000 mm |
| Light Source | Red Light |
| Service Life (T = +25 °C) | 100,000 h |
| Opening Angle | 4 ° |
| Light Spot Diameter | see Table 1 |
Electrical Data
| Sensor Type | Emitter |
| Supply Voltage | 10 … 30 V DC |
| Current Consumption (Ub = 24 V) | < 30 mA |
| Temperature Drift | < 10 % |
| Temperature Range | -40 … 60 °C |
| Reverse Polarity Protection | yes |
| Test input | yes |
| Protection Class | III |
Mechanical Data
| Housing Material | Plastic, ABS/PC |
| Degree of Protection | IP67 IP68 |
| Connection | M12 × 1; 4-pin |
| Optic Cover | Plastic, PMMA |
| Weight | 30 g |
Safety-relevant Data
| MTTFd (EN ISO 13849-1) | 4,534.36 a |
General Data
| Scope of delivery | 1 × initial start-up instructions 1 × sensor |
Adjustable parameters
| Other parameters | Emitted light |
| All other parameters can be found in the product documentation. |
Standards and certificates
![]() ![]() ![]() ![]() ![]() |
Table 1
| Distance transmitter/receiver | 1 m | 5 m | 20 m |
| Light Spot Diameter | 80 mm | 200 mm | 800 mm |
Connection Diagram
|
Ctrl. Panel
|
04 = Function Indicator
68 = Power LED |