Description
wenglor UniFlow flow sensors measure the flow rate of aqueous and oily media in closed piping systems. UniFlow flow sensors are very easy to operate thanks to the removable cover on the integrated display. The highly visible switching status display enables the rapid localization of affected sensors for maintenance processes. Thanks to the metallic sealing edge on the process connection, no further seals are required. This product has been discontinued. Click here to display similar products.
Features at a Glance
- Measurement independent of flow direction
- Hygienic design makes it easy to clean
- Highest precision of its class
- CIP-capable
- Temperature of the medium: 0 … 100° C (140° C for 24 hours without current measurement)
- FDA compliant
Technical Data
Sensor-specific data
| Selectable measuring range | 10 … 300 cm/s |
| Measuring range 1 | 10 … 150 cm/s |
| Setting range 1 | 15 … 150 cm/s |
| Measuring range 2 | 20 … 300 cm/s |
| Setting range 2 | 30 … 300 cm/s |
| Medium | Water |
| Measuring error (total) | 2 % |
| MTTFd (EN ISO 13849-1) | 1,194.55 a |
| Switching Hysteresis | 5 % |
| Temperature gradient | 30 K |
| Response time in case of temperature jump | 10 s |
Environmental conditions
| Temperature of medium | 0 … 100 °C |
| Temperature of the medium, short-term | 140 °C |
| Ambient temperature | -20 … 70 °C |
| Pressure Resistance | 60 bar |
| EMC | DIN EN 60947-5-9 |
| Shock resistance per DIN IEC 68-2-27 | 30 g / 11 ms |
| Vibration resistance per DIN IEC 60068-2-6 | 20 g (10…2000 Hz) |
Electrical Data
| Supply Voltage | 16 … 32 V DC |
| Current Consumption (Ub = 24 V) | 60 mA |
| Number of Switching Outputs | 1 |
| Analog Output | 4…20 mA |
| Signal source | Flow |
| Response Time | 1 … 5 s |
| Switching Output/Switching Current | < 250 mA |
| Switching Output Voltage Drop | < 2 V |
| Current Output Load Resistance | < 500 Ohm |
| Short Circuit Protection | yes |
| Reverse Polarity Protection | yes |
| Protection Class | III |
Mechanical Data
| Setting Method | Menu |
| Housing Material | Stainless steel, V4A (1.4435/316L) Plastic, PC |
| Material Control Panel | Polyester |
| Material in contact with media | Stainless steel, V4A (1.4404 / 316L) Stainless steel, V4A (1.4435/316L) |
| Degree of Protection | IP69K * IP67 * |
| Connection | M12 × 1; 4-pin |
| Process Connection | G 1/2″ CIP-capable |
| Process Connection Length (PCL) | 98 mm |
| Probe Length (PL) | 60 mm |
| Weight | 770 g |
General Data
| Scope of delivery | 1 × initial start-up instructions 1 × sensor |
Output
| Analog output flow | yes |
| PNP NO | yes |
Adjustable parameters
| Output | Analog Output PNP |
| Circuit | NC NC/NO NO |
| Other parameters | Selectable measurement range Switching point |
| All other parameters can be found in the product documentation. |
Standards and certificates
![]() ![]() ![]() ![]() ![]() |
Connection Diagram
|
Ctrl. Panel
|
01 = Switching Status Indicator
60 = display 20 = Enter key 22 = Up key 99 = Right button 0A = Detachable lid |
Complementary Products
|