ReeR Safety | SR ONE M

SR ONE M

Safety Interface for safety light curtains, with integrated Muting functions

In Stock
$248.33 per unit

Description

Safety Interface module for OSSD output devices. Safety light curtains: EOS4 A, EOS2 A, Admiral AD, Admiral AX BK, Vision V
Safety switches: Magnus RFID
Safety laser scanner: UAM

– 2 inputs for Muting sensors
– Guided contact safety relays
– Start/Restart interlock
– EDM Feedback input for extra external contactors monitoring
– Muting Time-out selectable
– Integrated Override with 2 operating modes selectable
– Muting Enable input. Whit clamp terminal blocks

Technical Data

Features

Safety level Type 4 – PL e
Safety level (SIL / PL) Type 4 – SILCL 3 – PL e – Cat. 4
Operating temperature (°C) – 30 … 55
Response time (ms) ≤ 20
Muting logic L (One way) logic with 2 sensors – Crossed beams
Muting timeout Selectable: 30 sec. or infinite
Muting inputs 2 at 24 VDC – PNP or relay – dark on
Signalling LEDs indication of power on, connected light curtains status, Muting status, Override status and fault diagnosis
Connections Removable terminal blocks, screw contacts
MTTFD (ISO13849) years The values depend on the type of use. Refer to the technical manual
PFHD (IEC 61508) The values depend on the type of use. Refer to the technical manual
Safety devices to be connected OSSD outpt devices. Safety light curtains: EOS4 A, EOS2 A, Admiral AD, Admiral AX BK, Vision V. Safety switches: Magnus RFID. Safety laser scanner: UAM
Start/Restart Automatic/Manual monitored selectable
Safety relay outputs 2 NO (6A at 250 VAC)
Packaging dimensions HxLxW (mm) 58 x 128 x 118
Product class A
Custom tariff 8536508090

Electrical data

Power supply (VDC) 24 ± 20%

Mechanical data

Dimensions HxWxD (mm) 99 x 35 x 114
Degree of protection IP2X
Fastening 35 mm DIN rail fastening according to EN 50022-35 standard

Documentation

Certificates & Compliance

Datasheets

Product Catalogues and Brochures

Sistema Libraries

Technical Manuals