S2FP004 Guard Locking Device Electromechanic, Power to Unlock Principle
Guard Locking Device
Applications: Safety Systems, Sensors & I/O
Description
The electromechanical guard locking device is distinguished by a high, continuously monitored locking force of 1150 N. This means that only one guard locking device is required to attain the Cat. 4 PL e safety level (EN ISO 13849-1). The safety level, as well as reaction time and risk time, remain unchanged when connected in series. Extensive diagnosis functions enhance system availability and simplify installation and maintenance. The unique star handle operating concept is especially well-suited for rotary and sliding doors. Thanks to RFID encoding and an actuator with teach-in function, the guard locking device demonstrates high levels of protection against manipulation.
Features at a Glance
- Performance Level: Cat. 4 PL e
- Power to unlock principle
- Continuously monitored locking force of 1150 N
Technical Data
Electrical Data
| Sensor Type | Locking unit |
| Supply Voltage | 20.4 … 26.4 V DC |
| Response Time | ≤ 100 ms |
| Risk time | ≤ 200 ms |
| Temperature Range | 0 … 60 °C |
| Storage temperature | -10 … 90 °C |
| Safety Output | OSSD |
| Number of safety outputs (OSSDs) | 2 |
| PNP Safety Output/Switching Current | 250 mA |
| Number of Signal Outputs | 1 |
| PNP signal output switching current | 50 mA |
| Short Circuit Protection | yes |
| Protection Class | III |
Mechanical Data
| Housing Material | Plastic |
| Degree of Protection | IP67 IP66 IP69 |
| Connection | M12 × 1; 8-pin |
| Latching Force, typical | 25 / 50 N |
| Weight | 736 g |
Safety-relevant Data
| Operating principle | RFID |
| Coding | Individual, teachable |
| Performance Level (EN ISO 13849-1) | Cat. 4 PL e * |
| PFHD | 5,20 × E-10 1/h * |
| Safety Integrity Level (EN 61508) | SIL 3* |
| Safety Integrity Level (EN 62061) | SILCL 3* |
| PDDB (EN 60947-5-3) | yes |
| Locking Device | Power to unlock principle |
| Locking force F (Zh) | 1,150 N |
General Data
| Applicable actuator | S2FP200 |
Function
| Series Connection | yes |
| Monitored lock | yes |
| Mechanical Detent Mechanism | yes |
| Detent Mechanism | yes |
| Auxiliary release | yes |
Standards and certificates
![]() ![]() ![]() ![]() ![]() ![]() |
Connection Diagram
|