The reflex sensor with background suppression works with blue light according to the angle measurement principle and is designed to detect objects against any background. The sensor always has the same switching distance, regardless of the color, shape and surface of the objects. The reflect sensor with blue light is specially designed for applications with dark shiny objects, such as when manufacturing solar wafers. The IO-Link interface can be used to configure the reflex sensors (PNP/NPN, NC/NO, switching distance), as well as for reading out switching statuses and distance values.

Features at a Glance

  • Condition monitoring
  • IO-Link 1.1
  • Reliably detect objects against any background
  • Blue light for dark, shiny objects

Technical Data

Optical Data

Range 400 mm
Setting Range 50 … 400 mm
Switching Hysteresis  < 3 %
Light Source Blue Light
Service Life (T = +25 °C) 100,000 h
Risk Group (EN 62471) 1
Max. Ambient Light 10,000 Lux

Electrical Data

Supply Voltage 15 … 30 V DC
Supply Voltage with IO-Link 18 … 30 V DC
Current Consumption (Ub = 24 V) < 20 mA
Switching Frequency 800 Hz
Switching Frequency (interference-free mode) 500 Hz
Response time (interference-free mode) 1.5 ms
Response Time 1.25 ms
Temperature Drift < 5 %
Temperature Range -40 … 60 °C
Switching Output Voltage Drop < 2 V
Switching Output/Switching Current 100 mA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Interface IO-Link V1.1
Protection Class III

Mechanical Data

Setting Method Potentiometer
Housing Material Plastic, ABS/PC
Degree of Protection IP67
IP68
Connection M12 × 1; 4-pin
Optic Cover Plastic, PMMA
Weight 33 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 917.7 a

General Data

Scope of delivery 1 × Z1PE002 mounting set
1 × initial start-up instructions
1 × sensor

Output

NPN NC, NPN NO yes
IO-Link yes

Adjustable parameters

Output Push-pull
NPN
PNP
Circuit NC
NO
inactive
Error output
NC+NO
Other parameters Off-delay
On-delay
Mode of operation
Hysteresis
Switching point
Emitted light
All other parameters can be found in the product documentation.

Standards and certificates

Table 1

Detection Range 50 mm 200 mm 400 mm
Light Spot Diameter 11 mm 13 mm 14 mm

Connection Diagram

Ctrl. Panel

30 = Switching Status/Contamination Warning
05 = Switching Distance Adjuster
68 = Power LED

Complementary Products

  • Protective Screen
  • IO-Link Master
  • Software
  • Protective housing set
  • Dust extraction tube

Documentation

CAD data

Datasheets

Declarations of Conformity / Approvals

ECAD data

Initial start-up instructions

Interface protocol

Operating instructions

Product certificates

Product Flyers