Wenglor | OPT1516

OPT1516 Reflex Sensor with Background Suppression

Reflex Sensor

In Stock
$266.00 per unit

Applications: Sensors & I/O

Description

These sensors have been specially designed for use in accumulation roller conveyors. Their compact design allows for installation between rollers below the transport level. High-precision background suppression makes it possible to reliably detect even black objects at up to 900 mm. The scaled switching-distance adjuster assures quick and simple adjustment to the desired distance. Thanks to the innovative fast-clip mounting system and quick wiring, the sensor are installed and ready for use in no time flat.

Features at a Glance

  • Scaled switching distance adjuster
  • Energy-saving
  • Time-saving installation with fast-clip mounting system
  • Optimized performance

Technical Data

Optical Data

Range 900 mm
Switching Hysteresis  < 5 %
Light Source Infrared Light
Wavelength 860 nm
Service Life (T = +25 °C) 100,000 h
Risk Group (EN 62471) 1
Max. Ambient Light 90,000 Lux
Opening Angle 3 °

Electrical Data

Supply Voltage 12 … 30 V DC
Current Consumption Sensor (Ub = 24 V) < 16 mA
Switching Frequency 100 Hz
Response Time 5 ms
Temperature Drift < 5 %
Temperature Range -40 … 60 °C
Number of Switching Outputs 1
Switching Output Voltage Drop < 0.9 V
PNP Switching Output/Switching Current 200 mA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Logic no
Protection Class III

Mechanical Data

Setting Method Potentiometer
Housing Material Plastic, ABS/GF
Degree of Protection IP67
Connection M12 × 1; 4-pin
Weight 41 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 1,471.92 a

General Data

Scope of delivery 1 × initial start-up instructions
1 × sensor

Output

PNP NC yes

Standards and certificates

Connection Diagram

Ctrl. Panel

30 = Switching Status/Contamination Warning
05 = Switching Distance Adjuster

Complementary Products

  • PNP-NPN Converter BG2V1P-N-2M
  • ZPTX001 Quick Mount

Documentation

CAD data

Datasheets

Declarations of Conformity / Approvals

Initial start-up instructions

Operating instructions

System solution