Wenglor | OHII102C0203

OHII102C0203 Reflex Sensor with Background Suppression

Reflex Sensor

In Stock
$697.85 per unit

Applications: Sensors & I/O

Description

The photoelectronic sensors in the hygienic housing are distinguished by a captive optic cover and food-safe, FDA-compliant materials. The hygienic design with no corners or edges enables optimal flow of cleaning agents. The laser-welded 316L stainless steel housing (1.4404/V4A) is resistant to high-pressure cleaning (degree of protection IP69K) and suitable for cleaning-intensive applications. When combined with the available accessories, gap-free installation is guaranteed for the highest hygiene requirements. Setting is performed by means of touch teach-in through the hermetically sealed housing. This product has been discontinued, but is still available as a spare part. Successor

Features at a Glance

  • Hygienic design makes it easy to clean
  • Made with food safe materials that are FDA approved
  • Waterproof (IP68/IP69K)
  • Touch teach-in, external teach-in

Technical Data

Optical Data

Range 100 mm
Setting Range 10 … 100 mm
Switching Hysteresis  < 5 %
Light Source Red Light
Service Life (T = +25 °C) 100,000 h
Max. Ambient Light 10,000 Lux

Electrical Data

Supply Voltage 10 … 30 V DC
Current Consumption (Ub = 24 V) < 30 mA
Switching Frequency 600 Hz
Response Time 800 µs
Temperature Drift < 10 %
Temperature Range -25 … 60 °C
Switching Output Voltage Drop < 2.5 V
PNP Switching Output/Switching Current 200 mA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Lockable yes
Teach Mode HT, VT
Protection Class III

Mechanical Data

Setting Method Teach-In
Housing Material Stainless steel, V4A (1.4404 / 316L)
Degree of Protection IP69K
IP68
Connection M12 × 1; 4-pin
Optic Cover Glass
Material Control Panel Plastic, PC (FDA)
Weight 98 g

General Data

Scope of delivery 1 × initial start-up instructions
1 × sensor
Approvals FDA compliant
Ecolab

Output

PNP NO yes
RS-232 with Adapterbox yes
External teach-in input yes

Adjustable parameters

Circuit NC
NC/NO
NO
All other parameters can be found in the product documentation.

Standards and certificates

Table 1

Detection Range 10 mm 40 mm 100 mm
Light Spot Diameter 2,5 × 7 mm 2,5 × 5 mm 2,5 × 2,5 mm

Connection Diagram

Ctrl. Panel

06 = Teach Button
02 = Contamination Warning
01 = Switching Status Indicator

Examples of Installation

Complementary Products

  • Adapterbox A232
  • PNP-NPN Converter BG2V1P-N-2M
  • Software

Documentation

CAD data

Datasheets

Declarations of Conformity / Approvals

ECAD data

Initial start-up instructions

Interface protocol

Operating instructions

Product certificates

System solution