Wenglor | OEEB302U0135

OEEB302U0135 Light Curtain for Measuring Tasks

Light Curtain

In Stock
$566.54 per unit

Applications: Sensors & I/O

Description

As these light curtains for measurement tasks are equipped with an integrated evaluation unit, external connection units are not needed. Objects are both recognized (via the digital output) and measured (via the analog output). The light curtains can be set up easily using the menu-controlled graphic display. Convenient parametrization and quick diagnosis is possible via the IO-Link interface.

Features at a Glance

  • Integrated evaluation unit
  • Object detection and measurement
  • 360° visible switching status display
  • Graphical display for easy operation

Technical Data

Optical Data

Range 3,000 mm
Measurement Field Height (MFH) 300 mm
Beam Distance 30 mm
Light Source Infrared Light
Service Life (T = +25 °C) 100,000 h
Max. Ambient Light 10,000 Lux
Opening Angle 10 °

Electrical Data

Sensor Type Receiver
Supply Voltage 18 … 30 V DC
Current Consumption (Ub = 24 V) < 50 mA
Switching Frequency 41 Hz
Response Time 12 ms
On-/Off-Delay 0 … 10 s
Temperature Drift < 10 %
Temperature Range -25 … 60 °C
Number of Switching Outputs 2
Switching Output Voltage Drop < 2.5 V
Switching Output/Switching Current 100 mA
Residual Current Switching Output < 50 µA
Analog Output 0…10 V
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Lockable yes
Interface IO-Link V1.0
Protection Class III

Mechanical Data

Setting Method Menu (OLED)
Housing Material Aluminum, powder-coated
Plastic, PC
Optic Cover Plastic, PC
Degree of Protection IP65
Connection M12 × 1; 5-pin
Weight 280 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 279.44 a

General Data

Scope of delivery 1 × initial start-up instructions
1 × sensor

Output

PNP NC yes
IO-Link yes
External teach-in input yes

Adjustable parameters

Analog output 0…10 V
4…20 mA
Output Error Output
Push-pull
PNP
Circuit NC
NC/NO
NO
Other parameters Off-delay
On-delay
All other parameters can be found in the product documentation.

Standards and certificates

Connection Diagram

Ctrl. Panel

20 = Enter key
22 = Up key
23 = Down key
60 = display

Complementary Products

  • IO-Link Master
  • Analog Evaluation Unit AW02
  • Software

Documentation

CAD data

Datasheets

Declarations of Conformity / Approvals

ECAD data

Initial start-up instructions

Operating instructions

Product Flyers

Quick-start guide