Wenglor | INTT311

INTT311 Inductive Sensor for Extreme Temperature Ranges

Inductive Sensor

In Stock
$1,466.77 per unit

Applications: Sensors & I/O

Description

Features at a Glance

  • Easy replacement thanks to quick-release fastener
  • Minimal mounting clearance thanks to wenglor weproTec
  • High tightness
  • Long service life at temperatures of up to 250 °C
  • Switching distance configurable via IO-Link

Technical Data

Inductive Data

Switching Distance 40 mm
Standard Target 120 × 120 mm
Correction Factors Stainless Steel V2A/CuZn/Al 1,10/0,65/0,58
Mounting Non-flush
Mounting A/B/C/D in mm 30/130/80/20
Mounting B1 in mm 0…70
Switching Hysteresis < 10 %

Electrical Data

Supply Voltage 10 … 30 V DC
Supply Voltage with IO-Link 18 … 30 V DC
Current Consumption (Ub = 24 V) < 15 mA
Switching Frequency 50 Hz
Temperature Drift < 10 %
Sensor head temperature range -10 … 250 °C
Temperature range of the plug 0 … 70 °C
Number of Switching Outputs 2
Switching Output Voltage Drop < 1.5 V
Switching Output/Switching Current 100 mA
Residual Current Switching Output < 100 µA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Interface IO-Link V1.1
Protection Class III
Service Life (T = +200 °C) 100,000 h
Service Life (T = +250 °C) 60,000 h

Mechanical Data

Sensing face Plastic, PEEK
Sensor head material Stainless steel, V2A (1.4305 / 303)
Analysis module material Stainless steel, V2A (1.4305 / 303)
Degree of protection, sensor head IP65
Degree of protection of the plug IP65
Connection M12 × 1; 4-pin
Cable length (L) 20 m
Cable Jacket Material Plastic, PFA
Outer diameter cable 3.4 mm
Bending Radius > 17 mm
PWIS-free yes
Weight 1,300 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 3,706.54 a

General Data

Scope of delivery 1 × initial start-up instructions
1 × MUTTER-M18-E003 hex nut
1 × sensor

Function

Error Indicator yes
Programmable switching distance 30/35/40 mm

Output

IO-Link yes
Error Output yes
PNP NO yes

Adjustable parameters

Output Error Output
Push-pull
NPN
PNP
Circuit NC
NC+NO
NO

Standards and certificates

Connection Diagram

Ctrl. Panel

01 = Switching Status Indicator

Complementary Products

  • IO-Link Master
  • Software

Documentation

CAD data

Datasheets

Declarations of Conformity / Approvals

ECAD data

Initial start-up instructions

Interface protocol

Operating instructions

Product certificates