These ultrasonic sensors evaluate the sound reflected from the object. They can detect almost any object and are especially well suited for monitoring fill levels of liquids and bulk goods and for detecting transparent objects. The sensor detects objects regardless of material, state of matter, color or degree of transparency. The sensors can be easily adjusted thanks to the 4-digit 7-segment display. The IO-Link interface makes parametrization and diagnosis quick and easy. The sensor can only be used in reflex mode operation.
Features at a Glance
- Digital and analog output
- Stainless steel housing
- Temperature drift eliminable
- Synchronous and multiplex mode
Technical Data
Ultrasonic Data
| Working Range | 200 … 3,000 mm |
| Measuring Range | 2,800 mm |
| Reproducibility maximum | 4 mm |
| Linearity Deviation | 4 mm |
| Resolution | 0.3 mm |
| Ultrasonic Frequency | 120 kHz |
| Opening Angle | < 14 ° |
| Service Life (T = +25 °C) | 100,000 h |
| Switching Hysteresis | 30 mm |
Electrical Data
| Supply Voltage | 18 … 30 V DC |
| Current Consumption (Ub = 24 V) | < 40 mA |
| Switching Frequency | 3 Hz |
| Response Time | 167 ms |
| Temperature Range | -30 … 60 °C |
| Number of Switching Outputs | 1 |
| Switching Output Voltage Drop | < 2.5 V |
| PNP Switching Output/Switching Current | 100 mA |
| Analog Output | 0…10 V |
| Synchronous Mode | up to 40 sensors |
| Multiplex Mode | up to 16 sensors |
| Short Circuit Protection | yes |
| Reverse Polarity Protection | yes |
| Overload Protection | yes |
| Lockable | yes |
| Interface | IO-Link V1.0 |
| Protection Class | III |
Mechanical Data
| Setting Method | IO-Link Menu (7-segment display) |
| Housing Material | Stainless steel, V2A (1.4305 / 303) Plastic, ABS |
| Sensing face | Epoxy resin/glass bubble mixture Plastic, PBT Silicone |
| Degree of Protection | IP67 |
| Connection | M12 × 1; 5-pin |
| Weight | 160 g |
Safety-relevant Data
| MTTFd (EN ISO 13849-1) | 725.66 a |
Output
| Error Output | yes |
| PNP NO | yes |
| Analog Output | yes |
| IO-Link | yes |
Adjustable parameters
| Analog output | 0…10 V 4…20 mA |
| Output | Error Output PNP |
| Circuit | NC NC/NO NO |
| Other parameters | Filter Multiplex mode Adjustable sonic cone Synchronous mode Teach mode |
| All other parameters can be found in the product documentation. |