Wenglor | UC66PA3

UC66PA3 Fiber-optic amplifier

Fiber-Optic Amplifier

In Stock
$317.00 per unit

Applications: Sensors & I/O

Description

These sensors are equipped for use with glass fiber optic cables but can be used with or without one. The transmitter and receiver are located in a single housing. The sensor evaluates transmitted light reflected back from the object and the output is switched as soon as an object passes the selected range. Bright objects reflect more light than dark objects, and can thus be recognized from greater distances.

Features at a Glance

  • Stainless steel housing
  • Adaptable for glass fiber-optic cables: reflex and through-beam mode
  • Large detection range
  • Adjustable detection range

Technical Data

Optical Data

Range 1,000 mm
Switching Hysteresis  < 15 %
Light Source Infrared Light
Service Life (T = +25 °C) 100,000 h
Max. Ambient Light 10,000 Lux
Opening Angle 12 °

Electrical Data

Supply Voltage 10 … 30 V DC
Current Consumption (Ub = 24 V) < 40 mA
Switching Frequency 1 kHz
Response Time 500 µs
Temperature Drift < 10 %
Temperature Range -25 … 60 °C
Switching Output Voltage Drop < 2.5 V
PNP Switching Output/Switching Current 200 mA
Residual Current Switching Output < 50 µA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Protection Class III

Mechanical Data

Setting Method Potentiometer
Housing Material Stainless steel, V2A (1.4305 / 303)
Optic Cover Plastic, PC
Full Encapsulation yes
Degree of Protection IP67
Connection M12 × 1; 4-pin
Weight 46 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 1,948.21 a

General Data

Scope of delivery 1 × BEF-SET-11 mounting set
1 × initial start-up instructions
1 × sensor

Output

PNP NC, PNP NO yes

Adjustable parameters

Circuit NC
NC+NO
NO

Standards and certificates

Connection Diagram

Ctrl. Panel

05 = Switching Distance Adjuster
02 = Contamination Warning
01 = Switching Status Indicator

Complementary Products

  • Glass Fiber-Optic Cable
  • PNP-NPN Converter BG2V1P-N-2M

Documentation

CAD data

Datasheets

Declarations of Conformity / Approvals

ECAD data

Initial start-up instructions

Operating instructions