Wenglor | P3PC001

P3PC001 Laser Distance Sensor Triangulation

Laser Distance Sensor

In Stock
$1,204.00 per unit

Applications: Sensors & I/O

Description

These laser distance sensors work with a fine red light beam and a high-resolution CMOS line. They determine the distance between the sensor and the object by means of the triangulation principle. Thanks to the integrated TripleA technology, the sensors offer high precision, temperature stability and material independence. This means they deliver accurate results even with objects of different materials, colors and shapes, as well as in fluctuating light and temperature conditions. The intuitive operating concept simplifies initial start-up and makes the sensors versatile all-rounders.

Features at a Glance

  • Switching point independent of material, color and brightness
  • 2 mutually independent switching outputs
  • Intuitive operating concept
  • Rugged aluminium housing
  • Integrated jump detection

Technical Data

Optical Data

Working Range 30 … 80 mm
Setting Range 30 … 80 mm
Reproducibility maximum 13 µm
Reproducibility: 1 Sigma 0.8 µm
Linearity Deviation 40 µm
Switching Hysteresis  < 0.5 %
Light Source Laser (red)
Wavelength 655 nm
Service Life (T = +25 °C) 100,000 h
Laser Class (EN 60825-1) 1
Max. Ambient Light 20,000 Lux
Light Spot Diameter see Table 1

Electrical Data

Supply Voltage 18 … 30 V DC
Current Consumption (Ub = 24 V) < 50 mA
Switching Frequency 650 Hz
Response Time  < 0.5 ms
Temperature Drift < 2.5 µm/K
Temperature Range -30 … 60 °C
Number of Switching Outputs 2
Switching Output Voltage Drop < 1.5 V
Switching Output/Switching Current 100 mA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Interface IO-Link V1.1
IO-Link Version 1.1
IO-Link transmission speed COM3
Protection Class III
FDA Accession Number 2310674-000

Mechanical Data

Setting Method Teach-In
Housing Material Aluminum, anodised
Plastic, ABS
Degree of Protection IP67
Connection M12 × 1; 5-pin
Optic Cover Plastic, PMMA
Weight 69 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 720.35 a

General Data

Scope of delivery 1 × initial start-up instructions
1 × sensor

Output

PNP NO yes
IO-Link yes

Adjustable parameters

Output Error Output
Push-pull
NPN
PNP
Circuit NC
NC/NO
NO
Other parameters Exposure time
Laser light
Switching hysteresis
Teach-in mode
Off-delay
On-delay
All other parameters can be found in the product documentation.

Standards and certificates

Table 1

Working Distance 30 mm 55 mm 80 mm
Light Spot Diameter 1,5 mm 1,5 mm 1,5 mm

Connection Diagram

Ctrl. Panel

06 = Teach Button
5a = Switching Status Indicator, O1
68 = Power LED
6a = Switching Status Indicator, O2

Complementary Products

  • Software
  • IO-Link Master
  • Protective Screen
  • Dust extraction tube

Documentation

CAD data

Datasheets

Declarations of Conformity / Approvals

ECAD data

Initial start-up instructions

Interface protocol

Operating instructions