These laser distance sensors work with a fine red light beam and a high-resolution CMOS line. They determine the distance between the sensor and the object by means of the triangulation principle. Thanks to the integrated TripleA technology, the sensors offer high precision, temperature stability and material independence. This means they deliver accurate results even with objects of different materials, colors and shapes, as well as in fluctuating light and temperature conditions. The intuitive operating concept simplifies initial start-up and makes the sensors versatile all-rounders.

Features at a Glance

  • Analog output: 4…20 mA
  • Graphical display for easy operation
  • Measured value independent of material, color and brightness
  • Rugged aluminium housing
  • Switching output

Technical Data

Optical Data

Working Range 150 … 1,000 mm
Measuring Range 150 … 1,000 mm
Reproducibility: 1 Sigma 35 µm
Linearity Deviation 750 µm*
Light Source Laser (red)
Wavelength 655 nm
Service Life (T = +25 °C) 100,000 h
Laser Class (EN 60825-1) 1
Max. Ambient Light 20,000 Lux
Light Spot Diameter see Table 1

Electrical Data

Supply Voltage 18 … 30 V DC
Current Consumption (Ub = 24 V) < 60 mA
Measuring Rate 2,500 /s
Response Time  < 0.5 ms
Temperature Drift < 75 µm/K
Temperature Range -30 … 60 °C
Analog Output 4…20 mA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Interface IO-Link V1.1
IO-Link transmission speed COM3
Protection Class III
FDA Accession Number 2311155-000

Mechanical Data

Setting Method Menu (OLED)
Housing Material Aluminum, anodised
Plastic, ABS
Degree of Protection IP67
Connection M12 × 1; 5-pin
Optic Cover Plastic, PMMA
Weight 188 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 397.4 a

General Data

Scope of delivery 1 × initial start-up instructions
1 × sensor

Output

PNP NO yes
Analog Output yes
IO-Link yes

Adjustable parameters

Output Error Output
Push-pull
NPN
PNP
Analog output 0…10 V
4…20 mA
Circuit NC
NC/NO
NO
Other parameters Exposure time
Laser light
Switching hysteresis
Teach-in mode
Off-delay
On-delay
All other parameters can be found in the product documentation.

Additional product information

External Information Filter 6 preset, A2 preset as switching output

Standards and certificates

Table 1

Working Distance 150 mm 575 mm 1000 mm
Light Spot Diameter 1 mm 1 mm 1 mm

Connection Diagram

Ctrl. Panel

5a = Switching Status Indicator, O1
68 = Power LED
7c = Analog Output Indicator, AO
20 = Enter key
60 = display

Complementary Products

  • Software
  • IO-Link Master
  • Protective Screen

Documentation

CAD data

Datasheets

Declarations of Conformity / Approvals

Initial start-up instructions

Interface protocol

Operating instructions

Product certificates

Product Flyers