Description
The reflex sensor works with red light according to the principle of energy and is designed to detect objects without a background. The switching distance is set for a given object. Note that: Bright objects reflect transmitted light better than dark objects. Dark (matte) objects can also be differentiated from bright (glossy) objects. This means that presence or stack height checks can be conducted or counting tasks carried out. The IO-Link interface can be used to configure reflex sensors (PNP/NPN, NC/NO, switching distance), as well as to output switching statuses and distance values. The robust V4A (1.4404/316L) stainless steel housing is resistant to oils and coolants, as well as cleaning agent.
Features at a Glance
- Condition monitoring
- Large detection range
- High switching frequency
- Robust stainless steel housing with IP69K
Technical Data
Optical Data
| Range | 700 mm |
| Switching Hysteresis | < 10 % |
| Light Source | Red Light |
| Service Life (T = +25 °C) | 100,000 h |
| Max. Ambient Light | 10,000 Lux |
Electrical Data
| Supply Voltage | 10 … 30 V DC |
| Supply Voltage with IO-Link | 18 … 30 V DC |
| Current Consumption (Ub = 24 V) | < 20 mA |
| Switching Frequency | 500 Hz |
| Switching frequency (speed mode) | 1,000 Hz |
| Response Time | 1 ms |
| Response time (speed mode) | 0.5 ms |
| Temperature Drift | < 10 % |
| Temperature Range | -40 … 60 °C |
| Switching Output Voltage Drop | < 2 V |
| Switching Output/Switching Current | 100 mA |
| Residual Current Switching Output | < 50 µA |
| Short Circuit Protection | yes |
| Reverse Polarity Protection | yes |
| Overload Protection | yes |
| Lockable | yes |
| Interface | IO-Link V1.1 |
| Protection Class | III |
Mechanical Data
| Setting Method | Potentiometer |
| Housing Material | Stainless steel, V4A (1.4404 / 316L) |
| Degree of Protection | IP68 IP69K |
| Connection | M8 × 1; 4-pin |
| Optic Cover | Plastic, PMMA |
| Weight | 42 g |
Safety-relevant Data
| MTTFd (EN ISO 13849-1) | 2,584.53 a |
General Data
| Scope of delivery | 1 × initial start-up instructions 1 × sensor |
| Approvals | Ecolab |
Output
| IO-Link | yes |
| PNP NC, PNP NO | yes |
Adjustable parameters
| Output | Push-pull NPN PNP |
| Circuit | inactive Error output NC NC+NO NO |
| Other parameters | Off-delay On-delay Mode of operation Hysteresis Switching point Emitted light |
| All other parameters can be found in the product documentation. |
Standards and certificates
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Table 1
| Detection Range | 100 mm | 300 mm | 700 mm |
| Light Spot Diameter | 20 mm | 40 mm | 80 mm |
Connection Diagram
|
Ctrl. Panel
|
30 = Switching Status/Contamination Warning
05 = Switching Distance Adjuster 68 = Power LED |