Wenglor | P2KE007

P2KE007 Through-Beam Sensor

Through-Beam Sensor

In Stock
$259.00 per unit

Applications: Sensors & I/O

Description

The through-beam sensor works with a fine laser beam as well as an emitter and receiver. The collimated class 1 laser beam detects objects, e.g., when conducting installation, feed, or presence checks, starting from a size of 1.0 mm, over the entire range. The emitter can be deactivated using test input in order to test the functionality of the through-beam sensor. The IO-Link interface can be used to configure the sensor (PNP/NPN, NC/NO, switching distance), as well as to read out switching statuses and signal values. The robust 316L stainless steel housing (1.4404/V4A) is resistant to oils, coolants, and cleaning agents.

Features at a Glance

  • IO-Link 1.1
  • Very high switching frequency
  • Test input for high operational reliability
  • Robust stainless steel housing with IP69K
  • Detect extremely small parts starting at 1 mm

Technical Data

Optical Data

Range 10,000 mm
Smallest Recognizable Part see Table 1
Switching Hysteresis  < 10 %
Light Source Laser (red)
Service Life (T = +25 °C) 100,000 h
Laser Class (EN 60825-1) 1
Max. Ambient Light 10,000 Lux

Electrical Data

Sensor Type Receiver
Supply Voltage 10 … 30 V DC
Supply Voltage with IO-Link 18 … 30 V DC
Current Consumption (Ub = 24 V) < 15 mA
Switching Frequency 4,500 Hz
Switching Frequency (interference-free mode) 2,000 Hz
Response Time 0.11 ms
Response time (interference-free mode) 0.25 ms
Temperature Drift (-10 °C < Tu < 40 °C) 10 % *
Temperature Range -40 … 50 °C
Switching Output Voltage Drop < 2 V
Switching Output/Switching Current 100 mA
Residual Current Switching Output < 50 µA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Interface IO-Link V1.1
Protection Class III

Mechanical Data

Setting Method Potentiometer
Housing Material Stainless steel, V4A (1.4404 / 316L)
Degree of Protection IP68
IP69K
Connection M8 × 1; 3-pin
Optic Cover Plastic, PMMA
Weight 42 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 1,913.81 a

General Data

Scope of delivery 1 × initial start-up instructions
1 × sensor
Approvals Ecolab

Output

PNP NC yes
IO-Link yes

Adjustable parameters

Output Push-pull
NPN
PNP
All other parameters can be found in the product documentation.

Standards and certificates

Table 1

Distance transmitter/receiver 1 m 6 m 10 m
Smallest Recognizable Part 2,5 mm 1,0 mm 1,5 mm

Connection Diagram

Ctrl. Panel

05 = Switching Distance Adjuster
30 = Switching Status/Contamination Warning
68 = Power LED

Complementary Products

  • IO-Link Master
  • Software

Documentation

CAD data

Datasheets

Declarations of Conformity / Approvals

ECAD data

Initial start-up instructions

Interface protocol

Operating instructions

Product certificates