P1PY208 Laser Distance Sensor Time of Flight
Laser Distance Sensor
Applications: Sensors & I/O
Description
The sensors function in accordance with the principle of transit time measurement with laser class 1. wintec with Dynamic Sensitivity technology (DS) enables previously unattainable reception sensitivity even with very weak signals. As a result, the sensors have a large working range of up to 10 m and can reliably detect dark or shiny objects even at extreme angles. wintec also works very reliably in adverse ambient conditions, such as those caused by ambient light or contamination. Extensive condition monitoring functions additionally enable predictive maintenance and trouble-free operation. Settings are entered via the easy-to-read OLED display or via Bluetooth using the weCon app.
Features at a Glance
- Analog output: 4…20 mA
- Wide working range and precise detection thanks to DS technology
- Wireless settings via Bluetooth
- Graphical display for easy operation
Technical Data
Optical Data
| Working Range | 0 … 10,000 mm |
| Measuring Range | 50 … 10,000 mm |
| Reproducibility maximum | 3 mm* |
| Linearity Deviation | 10 mm* |
| Light Source | Laser (red) |
| Wavelength | 660 nm |
| Service Life (T = +25 °C) | 100,000 h |
| Laser Class (EN 60825-1) | 1 |
| Beam Divergence | < 2 mrad |
| Max. Ambient Light | 100,000 Lux |
| Light Spot Diameter | see Table 1 |
| Reflector required | no |
Electrical Data
| Supply Voltage | 18 … 30 V DC |
| Current Consumption (Ub = 24 V) | < 60 mA |
| Measuring Rate | 100 /s* |
| Measuring Rate (max.) | 500 /s* |
| Temperature Drift | < 0.4 mm/K |
| Temperature Range | -40 … 50 °C** |
| Analog Output | 4…20 mA |
| Short Circuit Protection | yes |
| Reverse Polarity Protection | yes |
| Overload Protection | yes |
| Interface | IO-Link V1.1.3 |
| IO-Link transmission speed | COM3 |
| Protection Class | III |
| FDA Accession Number | 2412451-000 |
Mechanical Data
| Setting Method | (OLED)/Bluetooth menu |
| Housing Material | Plastic, ABS |
| Optic Cover | Plastic, PMMA |
| Degree of Protection | IP67 IP68 |
| Connection | M12 × 1; 5-pin |
| Weight | 45 g |
Safety-relevant Data
| MTTFd (EN ISO 13849-1) | 353.85 a |
General Data
| Scope of delivery | 1 × Z1PE002 mounting set 1 × initial start-up instructions 1 × sensor |
Output
| PNP NO | yes |
| Analog Output | yes |
| IO-Link | yes |
Adjustable parameters
| Output | Error Output Warning output |
| Analog output | 4…20 mA |
| Other parameters | Off-delay On-delay Sensitivity Filter Unit of measure Measuring mode Emitted light Sensor localization Teach mode |
| All other parameters can be found in the product documentation. |
Standards and certificates
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
Table 1
| Working Distance | 0 m | 5 m | 10 m |
| Light Spot Diameter | 5 mm | 10 mm | 15 mm |
Connection Diagram
|
– = supply voltage 0 V
+ = supply voltage + E/A1 = programmable input/output / IO-Link E3 = input O = analog output |
Ctrl. Panel
|
68 = Power LED
5a = Switching Status Indicator, O1 20 = Enter key 60 = display 7c = Analog Output Indicator, AO |