Wenglor | P1PH302

P1PH302 Reflex Sensor with Background Suppression

Reflex Sensor

In Stock
$380.00 per unit

Applications: Sensors & I/O

Description

The reflex sensor with background suppression works with red light according to the angle measurement principle. It has a IO-Link interface with a data storage function as well as additional configuration and diagnostic options. The interface can also be used to configure the sensors (PNP/NPN, NC/NO, switching distance, error output), as well as for reading out switching statuses and distance values. The teach-in function also provides another configuration option. Two independent switching outputs can be used, for instance, to monitor minimum and maximum values of distances or fill levels and stack heights.

Features at a Glance

  • Data storage
  • Wireless settings via NFC
  • High-end
  • IO-Link 1.1
  • Teach-in
  • Two independent switching outputs

Technical Data

Optical Data

Range 500 mm
Setting Range 60 … 500 mm
Switching Hysteresis  < 3 %
Light Source Red Light
Service Life (T = +25 °C) 100,000 h
Max. Ambient Light 10,000 Lux

Electrical Data

Supply Voltage 15 … 30 V DC
Supply Voltage with IO-Link 18 … 30 V DC
Current Consumption (Ub = 24 V) < 25 mA
Switching Frequency 150 Hz
Switching Frequency (1 Switching Output) 800 Hz
Response Time 3.3 ms
Response time (1 switching output) 1.25 ms
Temperature Drift < 5 %
Temperature Range -40 … 60 °C
Switching Output Voltage Drop < 2 V
Switching Output/Switching Current 100 mA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Interface IO-Link V1.1
Data Storage yes
Protection Class III

Mechanical Data

Setting Method Teach-in/NFC
Housing Material Plastic, ABS/PC
Degree of Protection IP67
IP68
Connection M12 × 1; 4-pin
Optic Cover Plastic, PMMA
Weight 33 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 886.3 a

General Data

Scope of delivery 1 × Z1PE002 mounting set
1 × initial start-up instructions
1 × sensor

Output

PNP NO yes
IO-Link yes
NFC interface yes

Adjustable parameters

Output Push-pull
NPN
PNP
Circuit NC
NO
NC/NO
Other parameters Off-delay
On-delay
Mode of operation
Hysteresis
Switching point
Emitted light
All other parameters can be found in the product documentation.

Standards and certificates

Table 1

Detection Range 60 mm 250 mm 500 mm
Light Spot Diameter 11 mm 13 mm 15 mm

Connection Diagram

Ctrl. Panel

06 = Teach Button
5a = Switching Status Indicator, O1
68 = Power LED
6a = Switching Status Indicator, O2
2a = NFC interface

Complementary Products

  • Protective Screen
  • IO-Link Master
  • Software
  • Protective housing set
  • Dust extraction tube

Documentation

CAD data

Datasheets

Declarations of Conformity / Approvals

ECAD data

Initial start-up instructions

Interface protocol

Operating instructions

Product certificates

Product Flyers