Description
The reflex sensor makes use of a red light line in accordance with the energetic principle and is suitable for detecting objects without any background. It’s suitable for reliable detection of objects with stamped or perforated surfaces such as PCBs and perforated sheet metal. Furthermore, objects can be detected on the light line regardless of position. The IO-Link interface can be used to configure the reflex sensor (PNP/NPN, NC/NO, switching distance), as well as for reading out switching statuses and distance values.
Features at a Glance
- Condition monitoring
- Detection of objects with variable position
- IO-Link 1.1
- Red light line for perforated or stamped objects
Technical Data
Optical Data
| Range | 100 mm |
| Switching Hysteresis | < 10 % |
| Light Source | Red Light (Line) |
| Service Life (T = +25 °C) | 100,000 h |
| Max. Ambient Light | 10,000 Lux |
| Light Spot Diameter | see Table 1 |
Electrical Data
| Supply Voltage | 10 … 30 V DC |
| Supply Voltage with IO-Link | 18 … 30 V DC |
| Current Consumption (Ub = 24 V) | < 20 mA |
| Switching Frequency | 500 Hz |
| Switching frequency (speed mode) | 750 Hz |
| Response time (speed mode) | 0.67 ms |
| Response Time | 1 ms |
| Temperature Drift | < 5 % |
| Temperature Range | -40 … 60 °C |
| Switching Output Voltage Drop | < 2 V |
| Switching Output/Switching Current | 100 mA |
| Residual Current Switching Output | < 50 µA |
| Short Circuit Protection | yes |
| Reverse Polarity Protection | yes |
| Overload Protection | yes |
| Lockable | yes |
| Interface | IO-Link V1.1 |
| Protection Class | III |
Mechanical Data
| Setting Method | Potentiometer |
| Housing Material | Plastic, ABS/PC |
| Degree of Protection | IP67 IP68 |
| Connection | M8 × 1; 4-pin |
| Optic Cover | Plastic, PMMA |
| Weight | 6 g |
Safety-relevant Data
| MTTFd (EN ISO 13849-1) | 1,718.95 a |
General Data
| Scope of delivery | 1 × initial start-up instructions 1 × sensor |
Output
| NPN NO | yes |
| IO-Link | yes |
Adjustable parameters
| Output | Push-pull NPN PNP |
| Circuit | NC NC/NO NO |
| Other parameters | Off-delay On-delay Mode of operation Hysteresis Switching point Emitted light |
| All other parameters can be found in the product documentation. |
Standards and certificates
![]() ![]() ![]() ![]() ![]() ![]() |
Table 1
| Detection Range | 30 mm | 65 mm | 100 mm |
| Light Spot Diameter | 10 x 35 mm | 11 x 70 mm | 12 x 100 mm |
Connection Diagram
|
Ctrl. Panel
|
05 = Switching Distance Adjuster
30 = Switching Status/Contamination Warning 68 = Power LED |
Complementary Products
|