OKII603C0103 Retro-Reflex Sensor for Transparent Objects
Retro-Reflex Sensor
Applications: Sensors & I/O
Description
The photoelectronic sensors in the hygienic housing are distinguished by a captive optic cover and food-safe, FDA-compliant materials. The hygienic design with no corners or edges enables optimal flow of cleaning agents. The laser-welded 316L stainless steel housing (1.4404/V4A) is resistant to high-pressure cleaning (degree of protection IP69K) and suitable for cleaning-intensive applications. When combined with the available accessories, gap-free installation is guaranteed for the highest hygiene requirements. Setting is performed by means of touch teach-in through the hermetically sealed housing.
Features at a Glance
- Made with food safe materials that are FDA approved
- Hygienic design makes it easy to clean
- Waterproof (IP68/IP69K)
- Touch teach-in, external teach-in
Technical Data
Optical Data
| Range | 6,000 mm |
| Reference Reflector/Reflector Foil | RQ100BA |
| Switching Hysteresis | < 5 % |
| Light Source | Red Light |
| Polarization Filter | yes |
| Service Life (T = +25 °C) | 100,000 h |
| Max. Ambient Light | 10,000 Lux |
| Opening Angle | 3 ° |
| Two-Lens Optic | yes |
Electrical Data
| Supply Voltage | 10 … 30 V DC |
| Current Consumption (Ub = 24 V) | < 40 mA |
| Switching Frequency | 1,600 Hz |
| Response Time | 313 µs |
| On-/Off-Delay (RS-232) | 0 … 5 s |
| Temperature Drift | < 5 % |
| Temperature Range | -10 … 60 °C |
| Switching Output Voltage Drop | < 2.5 V |
| PNP Switching Output/Switching Current | 200 mA |
| Residual Current Switching Output | < 50 µA |
| Short Circuit Protection | yes |
| Reverse Polarity Protection | yes |
| Overload Protection | yes |
| Lockable | yes |
| Teach Mode | NT, MT |
| Protection Class | III |
Mechanical Data
| Setting Method | Teach-In |
| Housing Material | Stainless steel, V4A (1.4404 / 316L) |
| Degree of Protection | IP69K IP68 |
| Connection | M12 × 1; 4-pin |
| Optic Cover | Plastic, PMMA (FDA) |
| Material Control Panel | Plastic, PC (FDA) |
| Weight | 101 g |
General Data
| Approvals | Ecolab FDA compliant |
Output
| PNP NC | yes |
| External teach-in input | yes |
| RS-232 with Adapterbox | yes |
Adjustable parameters
| Circuit | NC NC/NO NO |
| All other parameters can be found in the product documentation. |
Standards and certificates
![]() ![]() ![]() ![]() ![]() ![]() |
Connection Diagram
|
Ctrl. Panel
|
06 = Teach Button
02 = Contamination Warning 01 = Switching Status Indicator |
Examples of Installation
|
|
Reflector data
| RQ100BA | 0.03 … 6 m |
| RE18040BA | 0.04 … 4 m |
| RQ84BA | 0.04 … 4.7 m |
| RR84BA | 0.04 … 5.9 m |
| RE9538BA | 0.06 … 2.4 m |
| RE6151BM | 0.11 … 4.6 m |
| RR50_A | 0.03 … 3.5 m |
| RE6040BA | 0.02 … 4.5 m |
| RE8222BA | 0.03 … 2.7 m |
| RR34_M | 0.13 … 1.9 m |
| RE3220BM | 0.11 … 1.9 m |
| RE6210BM | 0.15 … 1 m |
| RR25_M | 0.08 … 1.5 m |
| RR25KP | 0.09 … 1 m |
| RR21_M | 0.07 … 1.6 m |
| Z90R001 | 0.06 … 1.2 m |
| ZRAE02B01 | 0.04 … 2.5 m |
| ZRME01B01 | 0.06 … 0.8 m |
| ZRME03B01 | 0.1 … 2.2 m |
| ZRMR02K01 | 0.06 … 0.9 m |
| ZRMS02_01 | 0.06 … 1.2 m |
| RF505 | 0.14 … 1.7 m |
| RF508 | 0.14 … 1.7 m |
| RF258 | 0.14 … 1.5 m |
| ZRDF__K01 | 0.14 … 4 m |
Complementary Products
|