Wenglor | OEEI202U0135

OEEI202U0135 Light Curtain for Measuring Tasks

Light Curtain

In Stock
$842.31 per unit

Applications: Sensors & I/O

Description

As these light curtains for measurement task are equipped with an integrated evaluation unit, external connection units are not needed. Objects are both recognized (via the digital output) and measured (via the analog output). The light curtains can be set up easily using the menu-controlled graphic display. Convenient parametrization and quick diagnosis is possible via the IO-Link interface. The adequate mounting angle BEF-SET-33 is included in the delivery.

Features at a Glance

  • Graphical display for easy operation
  • Integrated evaluation unit
  • Recognition of small parts
  • Object detection and measurement

Technical Data

Optical Data

Range 2,000 mm
Measurement Field Height (MFH) 200 mm
Beam Distance 2 mm
Light Source Infrared Light
Service Life (T = +25 °C) 100,000 h
Max. Ambient Light 10,000 Lux
Opening Angle 10 °

Electrical Data

Sensor Type Receiver
Supply Voltage 18 … 30 V DC
Current Consumption (Ub = 24 V) < 60 mA
Switching Frequency 45 Hz
Response Time 11 ms
On-/Off-Delay 0 … 10 s
Temperature Drift < 10 %
Temperature Range -25 … 60 °C
Number of Switching Outputs 2
Switching Output Voltage Drop < 2.5 V
Switching Output/Switching Current 100 mA
Residual Current Switching Output < 50 µA
Analog Output 0…10 V
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Lockable yes
Interface IO-Link V1.0
Protection Class III

Mechanical Data

Setting Method Menu (OLED)
Housing Material Aluminum, powder-coated
Plastic, PA
Plastic, PBT
Optic Cover Plastic, PC
Degree of Protection IP65
Connection M12 × 1; 5-pin
Weight 548 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 118.84 a

General Data

Scope of delivery 1 × BEF-SET-33 mounting set
1 × initial start-up instructions
1 × sensor

Output

PNP NC yes
IO-Link yes
External teach-in input yes

Adjustable parameters

Analog output 0…10 V
4…20 mA
Output Error Output
Push-pull
PNP
Circuit NC
NC/NO
NO
Other parameters Off-delay
On-delay
All other parameters can be found in the product documentation.

Standards and certificates

Connection Diagram

Ctrl. Panel

20 = Enter key
22 = Up key
23 = Down key
60 = display

Complementary Products

  • IO-Link Master
  • Analog Evaluation Unit AW02
  • Software

Documentation

CAD data

Datasheets

Declarations of Conformity / Approvals

ECAD data

Initial start-up instructions

Operating instructions

Product certificates

Product Flyers

Quick-start guide