Wenglor | I18H034

I18H034 Inductive Sensor with IO-Link

Inductive Sensor

In Stock
$128.00 per unit

Applications: Sensors & I/O

Description

The Inductive Sensors have not only been equipped with ASIC, but rather with an IO-Link interface as well for ideal integration into networks. As a result, a total of three switching distances and two switching frequencies can be selected, and PNP/NPN as well as NO/NC/antivalent options can be set as desired. This reduces the number of variants while simultaneously expanding the scope of functions.

Features at a Glance

  • Easy sensor configuration using the IO-Link interface
  • Minimal mounting clearance thanks to wenglor weproTec
  • Innovative ASIC circuit technology
  • Integrated error display and error output
  • Adjustable switching distance

Technical Data

Inductive Data

Switching Distance 12 mm
Standard Target 24 × 24 mm
Correction Factors Stainless Steel V2A/CuZn/Al 0,97/0,47/0,43
Mounting semi-flush
Mounting A/B/C/D in mm 18/46/36/5
Mounting B1 in mm 0…28
Switching Hysteresis < 10 %

Electrical Data

Supply Voltage 10 … 30 V DC
Supply Voltage with IO-Link 18 … 30 V DC
Current Consumption (Ub = 24 V) < 13 mA
Switching Frequency 500 Hz
Temperature Drift < 10 %
Temperature Range -40 … 80 °C
Switching Output Voltage Drop < 1 V
Switching Output/Switching Current 150 mA
Residual Current Switching Output < 100 µA
Short Circuit Protection yes
Overload Protection yes
Reverse Polarity Protection yes
Interface IO-Link V1.1
Protection Class III

Mechanical Data

Housing Material Brass, nickel-plated
Degree of Protection IP67
Connection M12 × 1; 4-pin
Weight 55 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 3,706.54 a

General Data

Scope of delivery 1 × MUTTER-M18-E001 hex nut
1 × sensor
Packaging unit 1 Piece

Function

Error Indicator yes
Programmable switching distance 8/10/12 mm
Programmable switching frequency yes

Output

IO-Link yes
Programmable error output yes
PNP NO yes

Adjustable parameters

Output Error Output
Push-pull
NPN
PNP
Circuit NC
NC/NO
NO
All other parameters can be found in the product documentation.

Additional product information

External Information switching distance presetting changed to 8 mm

Standards and certificates

Connection Diagram

Complementary Products

  • IO-Link Master
  • Software

Documentation

CAD data

Datasheets

Declarations of Conformity / Approvals

ECAD data

Initial start-up instructions

Interface protocol

Operating instructions

Product certificates