Wenglor | GM04VC2

GM04VC2 Gloss Sensor

Gloss Sensor

In Stock
$1,044.00 per unit

Applications: Sensors & I/O

Description

These sensors are capable of differentiating between surfaces with glossy and matte finishes. This allows for the monitoring of paint and adhesive layers, as well as drying status. This product has been discontinued, but is still available as a spare part. Successor Discontinuation Info

Features at a Glance

  • Adjustable gloss level
  • Practically independent of distance
  • Reliable differentiation between glossy and matte objects

Technical Data

Optical Data

Working Range 5 … 40 mm
Light Source Laser (red)
Wavelength 650 nm
Service Life (T = +25 °C) 100,000 h
Laser Class (EN 60825-1) 2
Max. Ambient Light 10,000 Lux
Light Spot Diameter see Table 1

Electrical Data

Supply Voltage 10 … 30 V DC
Current Consumption (Ub = 24 V) < 20 mA
Switching Frequency 1,900 Hz
Response Time 263 µs
Temperature Drift < 5 %
Temperature Range -25 … 60 °C
Switching Output Voltage Drop < 2.5 V
PNP Switching Output/Switching Current 200 mA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Protection Class III
FDA Accession Number 0820517-000

Mechanical Data

Setting Method Potentiometer
Housing Material Plastic, ABS
Plastic, PBT
Optic Cover Glass
Full Encapsulation yes
Degree of Protection IP67
Connection M12 × 1; 4-pin
Weight 33 g

General Data

Scope of delivery 1 × BEF-SET-02 mounting set
1 × initial start-up instructions
1 × sensor

Output

PNP NO/NC switchable yes

Adjustable parameters

Circuit NC
NC/NO
NO
All other parameters can be found in the product documentation.

Standards and certificates

Table 1

Remission from Object > 30 % ~ 18 % ~ 6 %
Working Distance 20 mm 15 mm 10 mm
Working Range ± 15 mm ± 10 mm ± 5 mm
Spot Size 6 × 20 mm 4,5 × 15 mm 3 × 10 mm

Connection Diagram

Ctrl. Panel

08 = NO/NC Switch
17 = Sensitivity Adjustment
01 = Switching Status Indicator

Complementary Products

  • PNP-NPN Converter BG2V1P-N-2M

Documentation

CAD data

Datasheets

Declarations of Conformity / Approvals

ECAD data

Initial start-up instructions

Notice of Discontinuation

Operating instructions