Technical Data
Sensor-specific data
| Measuring Range |
0 … 40 bar |
| Measurement Type |
relative |
| Maximum overload pressure |
80 bar |
| Bursting pressure |
120 bar |
| Medium |
Liquids, gases |
| Pressure response time (t90) |
< 1 ms |
| Measuring error (total) |
± 1 % |
Environmental conditions
| Temperature of medium |
-25 … 125 °C** |
| Ambient temperature |
-25 … 80 °C |
| Atmospheric humidity |
100% r.h. |
| Storage temperature |
-25 … 80 °C |
| EMC |
DIN EN 61326-2-3 |
| Shock resistance per DIN IEC 68-2-27 |
50 g / 11 ms |
| Vibration resistance per DIN IEC 60068-2-6 |
10 g (10…2000 Hz) |
Electrical Data
| Supply Voltage |
12 … 32 V DC |
| Current Consumption (Ub = 24 V) |
< 21 mA |
| Number of analog outputs |
1 |
| Analog Output |
4…20 mA |
| Signal source |
Pressure |
| Current Output Load Resistance |
< 500 Ohm |
| Short Circuit Protection |
yes |
| Reverse Polarity Protection |
yes |
| Protection Class |
III |
Mechanical Data
| Sensor element |
Stainless steel membrane |
| Housing Material |
Stainless steel, V4A (1.4404/316L) |
| Material in contact with media |
Stainless steel, V4A (1.4404 / 316L) Stainless steel, V4A (1.4548/630) Rubber, FKM |
| Degree of Protection |
IP68 * IP69K * |
| Connection |
M12 × 1; 4-pin |
| Process Connection |
G 1/2″ |
| Thread |
External thread |
| Seal material |
Fluororubber, FKM |
| Weight |
254 g |
Safety-relevant Data
| MTTFd (EN ISO 13849-1) |
3,283.16 a |
General Data
| Scope of delivery |
1 × initial start-up instructions 1 × sensor |
Standards and certificates